Power Supply & Transformer
Dedicated AC 48/65V transformers (configurable/customizable output, with adjustable 0–65V options) matched to PDLC film area. Input AC 110/220V. Over-voltage, over-current, overload, and short-circuit protection included.
Key Parameters
AC 48/65V
Output voltage
AC 110/220V
Input voltage
50/60 Hz
Frequency
OV + OC + OL + SC
Protection
3W – 1000W
Power range
Why a Dedicated Transformer Is Not Optional
PDLC smart film operates on AC 48/65V, not mains voltage. The transformer steps mains AC 110/220V down to AC 48/65V at 50/60 Hz for liquid crystal alignment. Output voltage is configurable and customizable to match your film model and project requirements. Direct connection to mains permanently damages the film within seconds.
An undersized transformer cannot maintain voltage under load. The film switches slowly or flickers, the transformer overheats, and switching reliability degrades over time. Always size the transformer to total film area at 3.7 W/m² plus a 20% safety margin.
All elevatoX transformers include over-voltage, over-current, overload, and short-circuit protection. Larger models (300W+) feature adjustable output voltage (AC 0–65V) for dimming control. Multi-channel models provide isolated outputs for independent zone control without additional relay hardware.
Standard Power Supplies (Single Channel)
Single isolated output, parallel-connected PDLC film. Master control — one switch controls the entire circuit, all film switches simultaneously. For single-zone spaces.
| Model | Power | Output | Control Area |
|---|---|---|---|
| 3W Black Power Supply | 3W | AC 48/65V | 0.4 m² |
| 30W Black Power Supply | 30W | AC 48/65V | 5 m² |
| 50W Black Power Supply | 50W | AC 48/65V | 8 m² |
| 100W Standard Power Supply | 100W | AC 48/65V | 15 m² |
| 200W Standard Power Supply | 200W | AC 48/65V | 30 m² |
Adjustable Power Supplies (0–65V Output)
Output voltage adjustable from AC 0–65V for dimming and fine-tuning. Same single-channel, master-control topology. Control via panel and remote.
| Model | Power | Output | Control Area |
|---|---|---|---|
| 300W Standard Power Supply | 300W | AC 0–65V (adjustable) | 50 m² |
| 400W Standard Power Supply | 400W | AC 0–65V (adjustable) | 60 m² |
| 500W Standard Power Supply | 500W | AC 0–65V (adjustable) | 75 m² |
| 600W Standard Power Supply | 600W | AC 0–65V (adjustable) | 90 m² |
| 700W Standard Power Supply | 700W | AC 0–65V (adjustable) | 100 m² |
| 800W Standard Power Supply | 800W | AC 0–65V (adjustable) | 120 m² |
| 1000W Standard Power Supply | 1000W | AC 0–65V (adjustable) | 140 m² |
| 50W Adjustable Power Supply | 50W | AC 0–65V (adjustable) | 8 m² |
| 100W Adjustable Power Supply | 100W | AC 0–65V (adjustable) | 15 m² |
| 200W Adjustable Power Supply | 200W | AC 0–65V (adjustable) | 30 m² |
Multi-Channel Power Supplies (Zone Control)
Each channel has an isolated output on the transformer secondary side with its own relay module. Independent zone control — switch each partition separately, single-channel failure does not affect others. For multi-zone commercial spaces.
| Model | Power | Output | Control Area | Circuit |
|---|---|---|---|---|
| Car 4CH Power Supply | 20W | AC 48/65V | 4 m² | 4-channel isolated output, independent zone control |
| 100W 6CH Power Supply | 100W | AC 48/65V | 15 m² | 6-channel isolated output, independent zone control |
| 200W 6CH Power Supply | 200W | AC 48/65V | 20 m² | 6-channel isolated output, independent zone control |
Vehicle Power Supplies
DC 12–24V input to AC 65V output for vehicle PDLC installations. Includes single-channel and multi-channel options for independent zone control.
| Model | Power | Input | Output | Circuit |
|---|---|---|---|---|
| Car Power Supply with Remote | 20W | DC 12–24V | AC 48/65V | Single isolated output, parallel-connected PDLC film |
| Car Adjustable Power Supply | 20W | DC 12–24V | AC 0–65V (adjustable) | Single isolated output, parallel-connected PDLC film |
Planning Tools
Size your transformer automatically with the cost calculator, or plan channel routing with the wiring simulator before requesting a quote.
Smart Film Cost Calculator
Estimate EXW price from your glass dimensions — area, transmittance, power draw, transformer sizing, and required sealant — then carry the configuration to the quote form.
Open tool →Wiring Simulator
Plan transformer sizing and channel routing for centralized or distributed layouts before final engineering review.
Open tool →Transformer & Power Supply
Match a power supply to your total film area — single channel, multi-channel, adjustable, and vehicle options.
Open tool →Frequently Asked Questions
Calculate total film area in square meters and multiply by 3.7 W/m² to get the ON-state power draw. Add a 20% safety margin. For example, 5 m² of PDLC film draws 18.5 W — add 20% margin for 22.2 W minimum transformer capacity. A 30W transformer covers this comfortably. Use the wiring simulator to calculate automatically.
An undersized transformer cannot maintain voltage under load. The film switches slowly or flickers between states, the transformer overheats, and the switching reliability degrades over time. Always size the transformer to total film area plus a 20% margin. Oversizing is safe — it simply costs more.
Yes, with a multi-zone controller. The transformer feeds the controller, which switches power to individual zones independently. The transformer must be sized to the sum of all zone areas, even though only some zones may be active simultaneously. This is the standard configuration for open-plan offices with multiple meeting rooms.
Yes. SPD film requires 90V AC, not the 48–65V AC used by PDLC. SPD transformers have different winding ratios and cannot be interchanged with PDLC transformers. Using the wrong voltage will damage the film.
Install the transformer in a dry, ventilated location away from direct moisture. For bathroom applications, mount it outside the bathroom or in a waterproof enclosure. For office installations, above the ceiling or in a service closet is common. Never expose the transformer to water spray or condensation.

Ready to Specify Your Transformer?
Request a quote with transformer sizing included.
Tell us your glass area and control layout. We return a matched transformer, wiring guide, and rollout plan.