Technical Specifications

Every Number Earns Its Place.

Review optical performance, electrical data, dimensional tolerances, and installation requirements before final specification.

01

Product Line Overview

Five models engineered for different balances of clarity, privacy depth, and viewing angle.

ModelStateHaze %VLT %IR Block %UV Block %Angle45deg VLT %Total VLT %
EL-L2OFF10074.47795.5145 deg1318
EL-L2ON2.5884.21260145 deg8490
EL-L2-PROOFF99.779.46893.8165 deg2025
EL-L2-PROON2.3684.51359165 deg8792
EL-X1OFF100777795.4150 deg1319
EL-X1ON1.8188.21058150 deg9094
EL-X2-AOFF10082.27396150 deg1523
EL-X2-AON1.4790.41570150 deg9195
EL-X2-PROOFF99.684.46595.9165 deg2227
EL-X2-PROON1.1392.21074165 deg9397
Test Conditions: values measured under standardized lab conditions. ON state is transparent under AC drive; OFF state is opaque and diffusive.
How to read this table: Haze indicates privacy depth in OFF state and clarity in ON state \\u2014 lower ON-haze means a clearer transparent view. VLT (Visible Light Transmittance) determines how much daylight passes through. IRR and UVR show heat and UV blocking performance \\u2014 higher values mean better comfort and protection. Viewing angle affects clarity when viewed from the side \\u2014 wider angles suit large partitions and boardrooms.
02

Physical and Electrical Performance

Validate compatibility with building electrical and glazing constraints before ordering.

Operating Voltage

65 V AC

Use dedicated transformer only — direct mains connection will damage the film.

Power Consumption

3.7 W/sqm

Low ON-state energy draw — costs less than a nightlight per square meter.

Switch ON Response

<= 60 ms

OFF to ON transition — fast enough to be instantaneous to human perception.

Switch OFF Response

<= 20 ms

ON to OFF — critical for instant privacy when needed.

Rated Lifespan

> 100k hrs

Continuous-duty capable — over 11 years of 24/7 operation.

Switching Cycles

> 200M

High durability for frequent use — switching 20×/day would take 27,000+ years to reach this limit.

Tested to GB18910.5-2008 and related in-house cycle and optical verification workflows.

02.5

Which Model Should You Choose?

Match model performance to your project priorities.

Maximum Clarity

EL-X2-A / EL-X2-PRO

Lowest ON haze (1.13\\u20131.47%) and highest VLT (90\\u201397%). Ideal for retail displays, projection screens, and any application where visual fidelity through the glass matters most.

Best Wide-Angle

EL-L2-PRO / EL-X2-PRO

165\\u00b0 viewing angle maintains clarity even when viewed from steep side angles. Recommended for conference rooms, boardrooms, and large partitions where people gather around the glass.

Best Value

EL-L2 / EL-L2-PRO

Balanced performance at entry-level pricing. ON haze of 2.36\\u20132.58% and VLT of 84\\u201390% \\u2014 excellent for most privacy applications where absolute top-tier clarity is not critical.

03

Dimensions and Format

Sheet, roll, and thickness constraints for procurement planning.

Maximum Single-Sheet Width

Lengths are custom per order in sheet or roll format.

1,800 mm

(70.87 in)

Sheet Widths1000 / 1200 / 1500 / 1800 mm
Sheet LengthCustom
Roll Widths1020 / 1220 / 1520 / 1820 mm
Max Roll Length<= 50 m
Core Diameter6 in
Selection guidance: Choose sheet format for ready-to-install projects with pre-cut dimensions. Choose roll format for high-volume custom processing \\u2014 roll film requires buyer-side electrode attachment and cutting tooling.
04

Installation Requirements

Correct installation protects film performance, warranty, and project reliability.

01. Dry Application Only

PDLC film is a dry-install product. Do not introduce water during application — moisture between the adhesive and glass causes bubbles and delamination.

02. Edge Clearance

Film should be 2-3 mm smaller than visible glass edges. This gap prevents electrical contact between the busbar and metal framing, which would cause short circuits.

03. Edge Sealing (Mandatory)

Seal immediately using neutral-cure, non-solvent, zero-shrink silicone. Typical quantity: 75 ml/sqm. Unsealed edges allow moisture ingress that corrodes busbar connections — the single most common cause of premature failure.

Tosseal 381GE 83DOWSIL 895DOWSIL 795Equivalent neutral cure sealant

04. Surface Preparation

Clean using IPA and lint-free cloth. Dust and grease degrade adhesion and optical quality — even microscopic particles create visible imperfections under the film.

05. Cutting Tolerance

Recommended precision: +/-0.5 mm. Roll-film processing requires dedicated tools — imprecise cutting leads to uneven edges and poor busbar contact.

06. Electrical Connection

Do not wire to mains directly. Use correctly sized transformer based on total film area. Undersized transformers overheat and reduce switching reliability.

05

Certifications and Standards

Reference standards and measurement workflows used for product verification.

Lifespan Test Standard

GB18910.5-2008

Switching Cycle Test

Independently conducted cycle testing workflow.

Optical Measurements

Haze meter, colorimeter, and LC parameter instrumentation.

06

Planning Tools

Size your project, plan wiring, and match power supplies alongside these specs.

Ready to Specify elevatoX?

If model, dimensions, and electrical requirements are clear, we are ready to proceed.

Specifications may be updated. Confirm the latest certified data sheets before final submission.